Job summary
The BCSe rectifier series by Statron offers user-friendly operation.
Tasks
- It features a microprocessor-controlled rectifier with alarms.
- High reliability and efficiency with low service costs.
- Designed for easy monitoring and long battery lifespan.
Skills
- Requires knowledge of power supply systems and rectifiers.
- Proficient in electrical engineering concepts.
- Ability to troubleshoot and maintain power systems.
Is this helpful?
Energy transmission
& distribution
Telecom
Industry
Infrastructure
The BCSe rectifier series is characterized by user-friendly operation and easy handling. The microprocessor-controlled
rectifier offers many
alarm and status contacts already in the standard version. RECTIFIER / BATTERY CHARGING SYSTEM BCSe
24/48/60/110/220V
Features
Advantages and benefits in operation Based on proven technology High reliability
Power factor corrected rectifier (PF 0.99) No reactive power loss
Easy to operate
Low service costs
Clearly structured simple display panel Easy operation and monitoring High efficiency
Low energy costs
Very low ripple voltage Extended battery life Designed for a service life of up to 20 years Long durability
Standard functions
- Switch-mode power supply technology (160 kHz)
- Compact design, small dimensions
- Digital volt- and ammeter
- Easy to understand and easy to operate HMI - Battery power switch included - Various DC voltages
- Power factor correction PF >0.99 12/24/48/60/110/220V
- Cable entry from below
- Short-circuit proof
Options
- Change of input from
3-phase to 1-phase
- Battery symmetry monitoring The options allow a tailor-made solution for specific - DC distribution requirements. The options are available as follows:
- 5 pcs. single-pole circuit breakers or 3 pcs. double-pole circuit breakers
- Batteries in the rectifier housing (48V systems)
- Sensor for temperature-controlled charging - Current capacity from 24V/400A up to 200V/50A - Additional relay card (8 separate alarms)
- Cabinets in special color
- Change of input from 1-phase
- Cabinets according to customer requirements to 3-phase with batteries and integrated distribution
Rated continuous current
12 V
5-35A (1-phase input)
24 V
2.5 -120A (1-phase input) 140 - 400A (3-phase input) 48 V
2.5 - 60A (1-phase input) 70 - 200A (3-phase input) 60 V
4 - 40A (1-phase input)
110 V
2.5 - 30A (1-phase input) 40 - 100A (3-phase input) 220 V
2.5 - 10A (1-phase input) 15 - 50A (3-phase input) AC input voltage (min. - max.) VAC
230V-15/+15%, 47-63Hz, 1-phase; 400V-15/+15%, 47-63Hz, 3-phase (model dependent) Output voltage
VDC
12 / 24 / 48 / 60 / 110 / 220 VDC Input power factor / cos phi PF/cos phi
0.99 / 0.99
DC voltage regulation
+/-0.05%
Output current limit
102% of rated current
Efficiency
>85%
Charging characteristic
I/U according to DIN 41773
Ripple voltage
< 0.05% RMS
Environmental conditions
°C
-10 to +40 °C
RH
95% humidity (non-condensing) m 1000m above sea level (without power reduction) Forced cooling per power module Protection class
IP40
Dimensions (WxDxH) without integrated batteries 430 x 175(270/365) x 410(700/1250)mm, model dependent Dimensions (WxDxH) with integrated batteries 600 x 300 x 1000 mm
Cabinet color
RAL 7035
Standard protection
Input circuit breaker, rectifier output & battery circuit breaker, short-circuit proof Standard alarms and status indicators on LCD Mains failure, rectifier failure, battery circuit failure, charging voltage failure (), high and alarm panel battery voltage, low battery voltage, earth fault +, earth fault -, load Potential-free contacts
3 pcs. standard alarms (A-/B-alarm, summary alarm), separate relay card as option Applicable main standards
EN 50 081-1 / -2 EMC emission, EN 50 082-1 / -2 EMC immunity EN 55022 B RFI/EMI, EN 60 950 Safety, IEC 60146-1-1 Basic requirements Quality/Environment
ISO 9001:2015/ISO 14001:2015
Further data on request